VRV / VRF systems for large commercial buildings
Equipment · VRV / VRF

VRV / VRF systems for large commercial buildings

VRV (Variable Refrigerant Volume, Daikin's brand for VRF) systems run one outdoor unit connected to many indoor units of mixed types — cassettes, ducted, wall-mounted — with independent per-zone control. The standard for offices and hotels above ~15 kW total load. Heat-recovery variants can heat one zone with the waste heat from cooling another, saving energy in mixed-use buildings.

Datasheets
04
Manufacturer
Daikin
Category
VRV / VRF
Updated
2026
01

Best-fit building types

  • Multi-storey offices
  • Hotels and student accommodation
  • Mixed-use commercial buildings
  • Retail parks
  • Data centres and process cooling
02

Typical applications

  • 5-15 storey commercial towers
  • Hotels with 40+ rooms
  • Student accommodation blocks
  • Mixed-tenant retail parks
  • Corporate HQ office buildings
03

Key benefits

01

One outdoor, many indoors

Cuts roof and plant-space requirements dramatically — one 30 kW outdoor can serve 15+ zones.

02

Heat recovery is real energy

In mixed-use buildings, waste heat from server rooms or south-facing offices heats north-facing meeting rooms — typical 25-40% seasonal energy saving.

03

Per-zone control

Every indoor unit runs its own setpoint and schedule — no zone fighting the others.

04

Modular scalability

Add indoor units later without changing the outdoor — the specifier's default for phased fit-outs.

04 · Datasheets

Daikin model families

  • 01
    RXYSCQ

    Mini VRV IV Heat Pump

    Entry-point VRV for smaller multi-zone buildings under ~15 kW total.

    Compact 3-phase VRV IV outdoor for small to mid-sized commercial buildings — drives up to nine indoor units across mixed types (cassette, ducted, wall-mounted). The step up from a multi-split when the project needs per-zone control, refrigerant piping over 30m, or BMS integration via DIII-Net.

  • 02
    RYYQ-U

    VRV IV Heat Pump

    Standard heat-pump VRV outdoor for offices, hotels and mixed commercial.

    VRV IV heat-pump outdoor for buildings that need heating and cooling but not simultaneous zone-to-zone. Modular 8-54 HP range, VRT (variable refrigerant temperature) control for seasonal efficiency gains, DIII-Net BMS integration.

  • 03
    REYQ-U

    VRV IV Heat Recovery

    3-pipe heat-recovery VRV — heat one zone using waste heat from cooling another.

    3-pipe VRV IV outdoor that lets the system heat and cool different zones simultaneously, recovering waste heat between them. Delivers typical 25-40% seasonal energy saving in mixed-use buildings (offices with server rooms, sun-side vs shade-side hotels, retail with cold storage).

  • 04
    REYA-A

    VRV 5 Heat Recovery

    Latest-generation R-32 heat-recovery VRV for new-build and BREEAM-scored projects.

    VRV 5 3-pipe heat-recovery outdoor on R-32 refrigerant — lower GWP than R-410A, higher seasonal efficiency, and reduced footprint versus VRV IV. The specifier default for new-build commercial where F-Gas phase-down and embodied-carbon reporting matter.

05

Frequently asked

What's the difference between VRV and VRF?
Nothing technically — VRV is Daikin's trademarked name for the same technology every other manufacturer calls VRF (Variable Refrigerant Flow). Both refer to variable-speed compressor systems that serve multiple indoor units from one outdoor.
When is VRV heat recovery worth the extra cost?
In buildings with simultaneous heating and cooling demand — mixed office/server rooms, hotels with sun-side and shade-side rooms, retail with cold storage next to public space. Payback typically 3-6 years on the capex premium.
By the numbers

VRV / VRF systems for large commercial buildings systems that outlast the buildings they sit in.”

20+
Years specifying Daikin equipment across UK commercial estates
04
Model families covered in this range
5 days
Full technical proposal turnaround after a site survey
06 · Related services
07 · Knowledge hub
Next step

Need help specifying?

Book a free specification survey — we'll size the equipment properly, cost the install, and issue a full technical proposal within 5 working days.

Other equipment types
All categories →